The coating of a low-hydrogen electrode, such as E7018, absorbs moisture from the air. That moisture brings hydrogen into the weld, which can cause porosity and delayed cracking.

Store them closed

Keep unopened packs in a dry place, off the floor. Once a sealed pack is open, move the electrodes into a heated oven.

Holding is not re-drying

  • Holding keeps dry electrodes dry, commonly at around 120 °C or more
  • Re-drying (baking) removes moisture already absorbed and needs a much higher temperature for a set time

Temperatures, times and the number of times a rod may be re-dried differ between products. Follow the electrode maker’s instructions and your welding procedure, and check that your oven reaches the temperature they ask for.

On site

Take out only what you will use shortly, and keep the rest in a portable oven that stays plugged in. Set aside electrodes that got wet or have a damaged coating.

For site work see the 5 kg and 10 kg ovens (50–300 °C). For the workshop there is a cabinet oven for 20, 40 or 100 kg.