Setting your welder: how many amps for 2.5, 3.2 or 4 mm electrodes?

A simple current chart by electrode diameter, the effect of position and the signs of a wrong setting.

Setting your welder: how many amps for 2.5, 3.2 or 4 mm electrodes?

The figures printed on the electrode box come first. These are typical values.

ElectrodeE6013E7018
2.5 mm60–90 A70–100 A
3.2 mm90–130 A90–140 A
4.0 mm140–180 A140–190 A

Use about 10 to 15 % less for vertical-up welding. Most basic electrodes run on DC with the holder on the positive terminal; check the box.

Wrong settings

A sticking electrode and a tall, narrow bead mean too little current. Heavy spatter, a glowing rod and undercut mean too much. Test on scrap and adjust in steps of 5 to 10 A.

See our welding machines and ground clamps.

Call us: +212 622 413 414 · Ask on WhatsApp